ÓÉÓÚpe¹Ü²»µ¼µç£¬²»µ¼´Å£¬ÎÞ·¨¶Ôpe¹Ü¾ÙÐÐ×·×Ù£¬¸øÈÕºóµÄ¹ÜµÀάÐÞ´øÀ´Î´±ã£¬Òò´Ëʾ×ÙÏßÒ²ËæÖ®·ºÆð ¡£ÏÖÔÚÊг¡Éϳ£ÓõÄʾ×ÙÏßÓУºÍ­°ü¸Ö²ÄÖÊʾ×ÙÏߣ¬±¡Ä¤¸Ö˿ѹÖÆʾ×ÙÏߣ¬µçÏßʾ×ÙÏß ¡£
Due to the non conductivity and non magnetism of the PE pipe, it is impossible to track the PE pipe, which brings inconvenience to future pipeline maintenance. Therefore, tracer lines also appear. The commonly used tracing wires in the current market include copper clad steel tracing wires, thin film steel wire pressed tracing wires, and wire tracing wires.
Ò»¡¢Ê¾×ÙÏßµÄ×÷ÓÃ
1¡¢ The role of tracer lines
“ʾ×ÙÏߔͬpe¹ÜÒ»ÆðÆÌÉ裻һÑùƽ³£»á½ÓÄɽðÊôÏßо£¬Í¨¹ý̽²â×°±¸¸ø“½ðÊôÏߔʩ¼ÓÐźÅ£¬ÓÉ̽²âÎüÊÕ»úÎüÊÕÐźÅ£¬´Ó¶øÕÒµ½Ê¾×ÙÏßµÄ׼ȷλÖ㬼´Í¬²½×·×Ùµ½peȼÆø¹ÜµÀµÄÏêϸλÖã»ÒÔ±ãÓÚ¶Ôpe¹ÜµÀ¾ÙÐÐˢм°Î¬ÐÞ ¡£
The "tracer line" is laid together with the PE pipe; Generally, metal wire cores are used to apply signals to the "metal wire" through detection equipment, and the detection receiver receives the signal to find the accurate position of the tracer line, that is, to synchronously track the specific position of the PE gas pipeline; To facilitate the renovation and maintenance of PE pipelines.
¶þ¡¢Ê¾×ÙÏßµÄÉú³¤
2¡¢ Development of Tracer Lines
ʾ×ÙÏßµÄÉú³¤¾­ÓÉËĴθÄÁ¼£º
The development of tracer lines has undergone four improvements:
1¡¢´úʾ×ÙÏߣºÊÇÓÉÂÁ²­ºÍËÜÁϱ¡Ä¤µÄĸÌå×é³É£¬ÂÁ²­Ö÷ÒªÊÇ´«ÊäÐźÅ£¬Ä¸ÌåÊÇÀο¿ÂÁ²­ ¡£ÕâÖÖʾ×ÙÏßÈõµã£ºÂÁ²­Ç¿¶ÈºÜÊǵÍ£¬×ÝÈ»ÔÚÉú²ú£¬ÔËÊäÀú³ÌÖÐÒ²ºÜÈÝÒ׶ÏÁÑ£¬¸¨ÉèÒ×ËðÉË£¬Í¬Ê±ÂÁ²­µÄµç×èºÜÊÇ´ó£¬ÓÐÓÃ̽²â¾àÀëºÍÉî¶ÈÓÐÏÞ ¡£
µØÂñʾ×ÙÏß
1. Tracer line: It is composed of a matrix of aluminum foil and plastic film, with aluminum foil mainly used for signal transmission and the matrix being fixed aluminum foil. The disadvantage of this tracer line is that the strength of aluminum foil is very low, and even during production and transportation, it is easy to break, and the auxiliary equipment is easily damaged. At the same time, the resistance of aluminum foil is very high, and the effective detection distance and depth are limited.
2¡¢µÚ¶þ´úʾ×ÙÏߣºÊÇÓɸÖË¿ºÍËÜÁϱ¡Ä¤Ñ¹Öƶø³É£¬¸Ãʾ×ÙÏßÓɸÖ˿Ϊµ¼Ì壬µç×è´ó£¬Ì½²â¾àÀëÓÐÏÞ£¬ÄÑÒÔÖª×ãÏÖʵÐèÒª ¡£
2. The second generation tracer line is made by pressing steel wire and plastic film. The tracer line is made of steel wire as the conductor, with high resistance and limited detection distance, making it difficult to meet practical needs.
3¡¢µÚÈý´úʾ×ÙÏߣºÊÇÓÉÍ­°ü¸Ö½ðÊôÏßоºÍpeÍâ±£»¤²ã×é³É£¬Íâ¹Û³ÉÏß×´ ¡£¸Ãʾ×ÙÏßµç×è¸ß£¬É쳤ÂʲÄÑÒÔÖª×㡶ÂñµØµçÀ¡·¹æ·¶ÒªÇó£¬Ì½²â¾àÀë½öΪ500Ã× ¡£
3. The third generation tracer wire is composed of a copper clad steel metal wire core and a PE outer protective layer, with a linear appearance. The tracer line has high resistance and poor elongation, making it difficult to meet the national standard requirements for buried cables. The detection distance is only 500 meters.
4¡¢µÚËÄ´úpe¸´ºÏÍ­°üÂÁºÏ½ðÏߣ¬ÊÇÓÉͭоÏߺÍÍ­°ü¸ÖÏßÉú³¤¶øÀ´µÄÐÂÐÍÏ߲ģ¬ÓÉÍ­°üÂÁºÏ½ðºÍpeÍâ±£»¤²ã×é³É£¬Íâ¹Û³ÉÏß×´£¬¼È±£´æÁËͭоÏߵĵ͵ç×裬ÓÖ±£´æÁËpe100µÄ³¤ÊÙÐÔ£¬¿É̽²â¾àÀëΪµ¥Ïò750Ã×£¡Ë«Ïò1500Ã×£¡ÒÔÖÐɽº£Ñ¶µÄhx14-2ΪÀý£¡
4. The fourth generation PE composite copper clad aluminum alloy wire is a national patented new type of wire developed from copper core wire and copper clad steel wire. It is composed of copper clad aluminum alloy and PE outer protective layer, with a linear appearance, retaining both the low resistance of the copper core wire and the longevity of the PE100. The detection distance is 750 meters in one direction! 1500 meters in both directions! Taking the Hx14-2 of Zhongshan Haixun as an example!